The “PIK-OFP” installation for studying core phase permeability (2 phases, desktop version)

The PIK-OFP installation is designed to determine filtration, capacitive and electrical core sample properties during single and two-phase stationary and non-stationary filtration at reservoir conditions. The equipment is used to determine oil displacement coefficients by water/gas for evaluating effectiveness of increasing oil recovery physicochemical methods, determining relative phase permeabilities in “liquid-liquid” and “liquid-gas” systems.

Request product cost
Benefits/Capabilities:
  • Compact desktop version
  • Automatic pore pressure maintenance
  • Installation set allows user to carry out experiments to study two-phase relative permeability according to OST 39-235-89
  • Ample opportunities for retrofitting equipment to expand the research range
Measured parameters

• Relative phase permeabilities during joint oil and water filtration in accordance with OST 39-235-89;
• Core sample current saturation
• Electrical resistivity
• Oen porosity coefficient at reservoir conditions
• Oil displacement rate
• Open porosity coefficient depending on changes at reservoir conditions

Technical specifications

Hydraulic system

Crimp pressure, MPa up to 70
Crimping pressure pump type manual
Pore ​​pressure, MPa up to 40
Pore pressure pump type automatic, single plunger
Reservoir pumps operating mode ·         maintaining  constant flow rate

·         • maintaining constant pressure
• maintaining  predetermined proportion when filtering two fluid phases through core sample from 0 to 100%

Working substance rate, ml / min 0,001¸50
Pressure maintenance accuracy from VPI, % 0,5
Flow rate maintenance accuracy, % from the current value 0,5
Cylinder volume, ml 200
Working substance • water with a salinity of – up to 300 g / l
• oil

Temperature maintenance system

Working temperature range, °C from +25 to +150
Heated elements core holder, supply pipes, pump hydraulic parts

Differential pressure measuring systems

Upper measurements limit, MPa 1,6
Measurement accuracy, % not more than ± 0,075

Fluid volume measurement systems

Type visual control
Meter separator volume, ml 200
Resolution, ml 0,1
Fluid-contacting parts material stainless steel, glass
Working pressure

 

atmospheric

Back pressure regulator

Pressure, MPa 40
Control automatic
Fluid-contacting parts material stainless steel, fluoroplastic, peek

Electrical resistance measurement module

Type Digital resistivity meter
Frequency, kHz 1
Accuracy, % 0,05
Measurement circuit 4 electrode

 

Core holder

Core diameter, mm 30
Maximum column length of core sample, mm 150
Maximum working crimp pressure, MPa 70
Maximum working pore pressure, MPa 40
Maximum working temperature, °С up to 150
Resistivometric saturation control 4-electrode circuit
Fluid-contacting parts material stainless steel

 

PC-based monitoring and control system

Control pumps flow rate, temperature, back pressure regulator
Data collection pressure/differential pressure digital sensors, pumps flow rate, thermocouples, separator meter, sample electrical resistance